Telemetry, saved runs and share links
The Telemetry card on System Health charts the readings your collectors have sent, one chart per reading, for one system at a time. Every point is a reading a collector reported. Avrel does not fill gaps or estimate values: if the collector or controller was offline, the chart shows a gap.
Live#
When LIVE is lit, the charts follow incoming readings and the window moves with the clock. Collectors report about once a minute, so new points appear at that pace.
Looking back in time pauses the charts: zoom into a range, or click a chart to pin the cursor. The button then reads PAUSED. Choose Go live to follow incoming readings again. Clicking LIVE also pauses.
Choose a time range with 15m, 1h, 6h, 24h or 7d. Avrel keeps 30 days of readings. Longer ranges average readings into time buckets so the chart stays readable; zoom in to see every reading.
Sync#
With Sync on, every chart shares one cursor and one time range. Hover over 14:02 on one chart and every chart shows its reading at 14:02. Zoom into one chart and they all zoom.
- Zoom in: drag across a chart.
- Zoom out: double-click a chart.
- Pin the cursor: click a chart. Click the same spot again to unpin it.
Turn Sync off to zoom or hover one chart on its own.
On Incident Replay, Sync links the replay charts and the 3D twin: hovering a chart moves the cursor on every chart and shows that moment on the twin. Click or tap a chart to set the replay position. An incident is a recording, so the button reads RECORDED; Go live opens the live readings for the same system.
Replay speed and stepping#
On Incident Replay, Play runs the recording at its real speed. The speed menu next to it slows playback to 0.5×, 0.25× or 0.1× for close inspection, or speeds it up to 2× or 5×. The ◀ and ▶ buttons move one sample at a time. On a keyboard, the Left and Right arrows do the same (hold Shift to move 10 samples), and Space plays or pauses.
Saved runs#
A saved run keeps a copy of the readings in a time window, for example a test, a commissioning step or the hour before a fault.
- On System Health, choose the system and the window you want. Zoom in if you need to.
- Choose Save run, give it a name and choose Save run again.
Saved runs are listed in the sidebar under Saved runs, with their start time, length and system. They belong to the organization, so every member can open them, and they stay after the 30-day reading history is cleared.
- Open a run: click it in the sidebar. The button reads RECORDED and the window is the run's own.
- Compare a run: drag it from the sidebar onto the charts, or choose Compare next to it. Its readings are drawn as dashed lines, lined up with the start of the window you are looking at.
- Delete a run: open it and choose Delete. The person who saved it and owners can delete it.
With demo data turned on, saved runs are kept with the demo data and are shown only while demo data is on.
Share links#
Share copies a link to exactly what you are looking at: the system, the time window, the pinned cursor, the saved run and any runs you are comparing. On Incident Replay it links to the incident, the replay position and the zoom.
A share link carries view settings, not data. Only signed-in members of your organization can open it. Someone who is not signed in is asked to sign in first and then lands on the same view. Someone who is not a member sees nothing from the organization.
Investigate with AI#
On Incident Replay, Investigate with AI asks Claude to read the incident: every recorded channel and event, the declared topology, the audit findings, your release records and the regression checks you already have. It drafts:
- a root cause, with the evidence it rests on cited by channel and time (click a citation to jump the replay and the twin to that moment),
- the topology parts and audit rules involved, what the release records show, and the other explanations it ruled out,
- one regression check for the release gate: a minimum or maximum on one channel.
Nothing is saved until you press Accept. Before you see the draft, the server re-reads every cited value from the recording and drops any citation the recording does not contain, and replays the proposed check against the recording to show whether it reproduces the fault. Accepted investigations stay on the incident, and their check appears on HIL CI & Release Gate marked AI-drafted, with who accepted it. Claude does not write firmware or change anything on your equipment.
The incident data you investigate is sent to Anthropic's API to produce the draft. Hosting operators turn the feature on by setting ANTHROPIC_API_KEY on the server.